Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
1.
Rev. bras. cir. cardiovasc ; 34(3): 344-351, Jun. 2019. tab, graf
Article in English | LILACS | ID: biblio-1013473

ABSTRACT

Abstract Objectives: To compare the advantages and disadvantages of perventricular and percutaneous procedures for treating isolated ventricular septal defect (VSD). Methods: A total of 572 patients with isolated VSD were selected in our hospital between January 2015 and December 2016. The patients' median age and weight were five years (1-26 years) and 29 kg (9-55 kg), respectively. The median diameter of VSD was 6.0 mm (5-10 mm). Patients were divided into two groups. In group A, perventricular device closure was performed in 427 patients; in group B, 145 patients underwent percutaneous device closure. Results: Four hundred twelve patients in group A and 135 patients in group B underwent successful closure. The total occlusion rate was 98.5% (immediately) and 99.5% (3-month follow-up) in group A, which were not significantly different from those in group B (97.7% and 100%, respectively). Patients in group A had longer intensive care unit (ICU) stay than those in group B, but patients in group B experienced significantly longer operative times than those in group A. The follow-up period ranged from 8 months to 1.5 year (median, 1 year). During the follow-up period, late-onset complete atrioventricular block occurred in two patients. No other serious complications were noted in the remaining patients. Conclusion: Both procedures are safe and effective treatments for isolated VSD. The percutaneous procedure has obvious advantages of shorter ICU stay and less trauma than the perventricular procedure. However, the perventricular procedure is simpler to execute, results in a shorter operative time, and avoids X-ray exposure.


Subject(s)
Humans , Male , Female , Infant , Child, Preschool , Child , Adolescent , Adult , Young Adult , Septal Occluder Device/standards , Heart Septal Defects, Ventricular/surgery , Aortic Valve Insufficiency/surgery , Time Factors , Angiography/methods , Echocardiography/methods , Retrospective Studies , Treatment Outcome , Statistics, Nonparametric , Equipment Design , Atrioventricular Block/surgery , Operative Time , Heart Septal Defects, Ventricular/diagnostic imaging , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Length of Stay
2.
Rev. bras. cir. cardiovasc ; 29(3): 330-337, Jul-Sep/2014. tab, graf
Article in English | LILACS, SES-SP | ID: lil-727173

ABSTRACT

Objective: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. Methods: This study was performed in 52 patients (51% males), between 20 to 80 (67±14.4) years old weighing 53 to 102 (71.7±12.6) kg, mostly under myocardial revascularization surgery (34.6%) and valvular surgery (32.8%). Besides the routine evaluation of the data observed in these cases, we monitored pump rotational speed, blood flow, cardiopulmonary bypass duration, urine free hemoglobin for blood cell trauma analysis (+ to 4+), lactate desidrogenase (UI/L), fibrinogen level (mg/dL) and platelet count (nº/mm3). Results: Besides maintaining appropriate blood pressure and metabolic parameters it was also observed that the Free Hemoglobin levels remained normal, with a slight increase after 90 minutes of cardiopulmonary bypass. The Lactate Dehydrogenase showed an increase, with medians varying between 550-770 IU/L, whereas the decrease in Fibrinogen showed medians of 130-100 mg/dl. The number of platelets showed a slight decrease with the medians ranging from 240,000 to 200,000/mm3. No difficulty was observed during perfusion terminations, nor were there any immediate deaths, and all patients except one, were discharged in good condition. CONCLUSION: The Spiral Pump, as blood propeller during cardiopulmonary bypass, demonstrated to be reliable and safe, comprising in a good option as original and national product for this kind of application. .


Objetivos: Apresentar resultados da aplicação da bomba espiral que emprega efeitos hidráulicos centrífugo e axial de bombeamento como elemento propulsor do circuito de circulação extracorpórea em pacientes submetidos a cirurgias cardíacas após modificações introduzidas no design do projeto original. Métodos: O estudo foi realizado em 52 pacientes (51% masculinos), com idade entre 20 a 80 (67±14,4) anos, peso 53 a 102 (71,7±12,6) kg, submetidos na maioria a cirurgia de revascularização miocárdica (34,6%) e Orovalvar (32,8%). Além das avaliações rotineiras, foram registrados rotação, tempo de CEC e para análise do impacto traumático à crase sanguínea, hemoglobina livre na urina (+ a 4+), desidrogenase láctica, fibrinogênio (mg/dL) e contagem de plaquetas (nº/mm3). Resultados: Observou-se a manutenção de parâmetros pressóricos e metabólicos adequados. Quanto aos marcadores de danos à crase sanguínea, as alterações estiveram proporcionais ao tempo maior de circulação extracorpórea. Os níveis de Hemoglobina Livre permaneceram com valores normais, com ligeiro aumento a partir dos 90 minutos de circulação extracorpórea. A Desidrogenase Láctica mostrou aumento, variando as medianas entre 550 a 770 UI/L enquanto o Fibrinogênio mostrou queda das medianas de 130 a 100 mg/dl. O número de plaquetas mostrou ligeira queda das medianas variando entre 240.000 a 200.000/mm3. Não ocorreram dificuldades de saída de perfusão, não se observou óbito imediato e todos os pacientes, exceto 1, obtiveram alta hospitalar. Conclusão: A bomba espiral aplicada como bomba propulsora de sangue durante cirurgia cardíaca se mostrou confiável e segura, não causou impacto traumático ...


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Cardiac Surgical Procedures/instrumentation , Cardiopulmonary Bypass/instrumentation , Heart-Assist Devices/standards , Cardiac Surgical Procedures/methods , Cardiopulmonary Bypass/methods , Equipment Design/standards , Equipment Safety , Fibrinogen/analysis , L-Lactate Dehydrogenase/blood , Medical Illustration , Models, Cardiovascular , Platelet Count , Reproducibility of Results , Statistics, Nonparametric , Time Factors , Treatment Outcome
5.
Ann Card Anaesth ; 2010 May; 13(2): 169-175
Article in English | IMSEAR | ID: sea-139523

ABSTRACT

The surgical procedures performed with robtic assitance and the scope for its future assistance is endless. To keep pace with the developing technologies in this field it is imperative for the cardiac anesthesiologists to have aworking knowledge of these systems, recognize potential complications and formulate an anesthetic plan to provide safe patient care. Challenges posed by the use of robotic systems include, long surgical times, problems with one lung anesthesia in presence of coronary artery disease, minimally invasive percutaneous cardiopulmonary bypass management and expertise in Trans-Esophageal Echocardiography. A long list of cardiac surgeries are performed with the use of robotic assistance, and the list is continuously growing as surgical innovation crosses new boundaries. Current research in robotic cardiac surgery like beating heart off pump intracardic repair, prototype epicardial crawling device, robotic fetal techniques etc. are in the stage of animal experimentation, but holds a lot of promise in future.


Subject(s)
Anesthesia/methods , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Cardiac Surgical Procedures/trends , Catheterization , Humans , Patient Positioning , Patient Selection , Robotics/methods , Robotics/trends , Robotics/statistics & numerical data
6.
Ann Card Anaesth ; 2010 May; 13(2): 148-153
Article in English | IMSEAR | ID: sea-139517

ABSTRACT

A pacing system infection may lead to infective endocarditis and systemic sepsis. Tricuspid valve surgery may be required if the valve is severely damaged in the process of endocarditis. Although, cardiopulmonary bypass is the safe choice for performing right-heart procedures, it may carry risk of inducing systemic inflammatory response and multi-organ dysfunction. Some studies have advocated TV surgery without institution of CPB. We report tricuspid valve excision using the off-pump inflow occlusion technique in a 68-year-old man. We also describe role of intra-operative TEE as a monitoring tool at different stages of the surgical procedure. .


Subject(s)
Aged , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Coronary Artery Bypass, Off-Pump/methods , Echocardiography, Transesophageal/methods , Endocarditis, Bacterial/complications , Endocarditis, Bacterial/surgery , Humans , Male , Monitoring, Intraoperative , Sick Sinus Syndrome/surgery , Treatment Outcome , Tricuspid Valve/surgery , Tricuspid Valve/diagnostic imaging , Ultrasonography, Interventional/methods
7.
Ann Card Anaesth ; 2009 Jan-Jun; 12(1): 40-8
Article in English | IMSEAR | ID: sea-1512

ABSTRACT

Atrial septal defect is usually closed in the cardiac catheterisation laboratory using atrial septal occluder (ASO) device. One of the complications associated with the procedure is embolisation of the device into the pulmonary artery. We are reporting two cases wherein the pulmonary embolisation of ASO device occurred during the procedure in one patient and in the early post-procedure period in another; both were retrieved surgically. We are also describing the haemodynamic consequences of this complication and the role of intraoperative transoesophageal echocardiography during surgical retrieval of the device.


Subject(s)
Adult , Bioprosthesis/adverse effects , Blood Gas Analysis , Cardiac Surgical Procedures/instrumentation , Device Removal/methods , Echocardiography , Female , Foreign-Body Migration/surgery , Heart Septal Defects, Atrial/surgery , Humans , Hypotension/etiology , Male , Monitoring, Intraoperative , Pulmonary Artery , Pulmonary Embolism/etiology , Treatment Outcome , Young Adult
9.
Rev. bras. cir. cardiovasc ; 22(1): 41-48, jan.-mar. 2007. ilus, graf
Article in Portuguese | LILACS, SES-SP | ID: lil-454626

ABSTRACT

OBJETIVO: A Síndrome de Hipoplasia de Câmaras Esquerdas representa um grande desafio para cirurgiões do mundo inteiro. Atualmente, tem sido proposto procedimento paliativo alternativo, por meio da bandagem bilateral das artérias pulmonares associada à colocação de stent no canal arterial e atrioseptostomia. No entanto, as bandagens utilizadas são fixas, podendo tornar-se inadequadas após o fechamento do esterno ou com o rápido crescimento somático do paciente. Descrevemos a primeira aplicação clínica do novo dispositivo miniaturizado de bandagem ajustável das artérias pulmonares em neonato portador da síndrome de hipoplasia de câmaras esquerdas, o qual permitiu ajustes percutâneos precisos do fluxo sangüíneo pulmonar. MÉTODO: Através de esternotomia mediana, neonato de 5 dias de vida foi submetido à bandagem pulmonar bilateral, usando este novo dispositivo, combinada com interposição de tubo de PTFE entre o tronco pulmonar e o tronco braquiocefálico. RESULTADOS: O paciente apresentou boa evolução pós-operatória. Três ajustes percutâneos das bandagens foram necessários para manter a saturação arterial de oxigênio entre 75-85 por cento. No 48° dia de vida, o paciente foi submetido a atrioseptostomia com colocação de stent (6 mm) para tratamento de comunicação interatrial restritiva. No 106° dia de vida, realizou-se operação de Norwood associada à anastomose cavopulmonar bilateral. As bandagens foram removidas, sem distorção das artérias pulmonares. CONCLUSÕES: O uso clínico deste sistema inovador de bandagem ajustável das artérias pulmonares mostrou-se factível, seguro e eficaz. Permitiu o ajuste fino do fluxo pulmonar de acordo com as necessidades clínicas, proporcionando um equilíbrio preciso entre as circulações pulmonar e sistêmica.


OBJECTIVE: Hypoplastic left heart syndrome remains a challenge for worldwide surgeons. Initial palliation employing bilateral pulmonary artery banding along with ductal stent implantation and atrial septostomy has been proposed as an alternative approach. However, the surgically placed bands are fixed and may become inadequate after sternum closure or with somatic growth of the patient. We describe the first case in which a neonate with hypoplastic left heart syndrome was initially managed using a mini banding system that allows for fine percutaneous adjustments of pulmonary blood flow. METHOD: Through a mid sternotomy, a 5 day-old neonate underwent bilateral pulmonary artery banding using this new system combined with placement of a main pulmonary artery to innominate artery shunt. RESULTS: The patient had an uneventful postoperative course. Three percutaneous adjustments of the banding system were necessary to keep the arterial oxygen saturation in the 75 percent-85 percent range. On the 48th day of life, she was submitted to stent placement (6 mm) within the atrial septum to treat a restrictive atrial septal defect. The Norwood operation and the bidirectional Glenn shunt were carried out on the 106th day of life. The bands were removed with no distortion of the pulmonary arteries. CONCLUSIONS: The clinical use of this innovative pulmonary artery banding system was feasible, safe and effective. It allowed for customization of the pulmonary blood flow according to the underlying clinical needs, resulting in a more precise balance between the pulmonary and systemic circulations.


Subject(s)
Female , Humans , Infant, Newborn , Cardiac Surgical Procedures/instrumentation , Hypoplastic Left Heart Syndrome/surgery , Pulmonary Artery/surgery , Hypoplastic Left Heart Syndrome/physiopathology , Palliative Care , Pulmonary Circulation
10.
Rev. bras. cir. cardiovasc ; 20(4): 377-381, set.-dez. 2005. ilus
Article in Portuguese | LILACS | ID: lil-423289

ABSTRACT

OBJETIVO: Os pacientes com lesão isolada da artéria coronária descendente anterior (ADA) se beneficiam mais do tratamento cirúrgico do que com intervencão percutânea. Entretanto, com a menor invasividade da intervencão percutânea, a maioria dos pacientes tem sido direcionada para este procedimento. Relatamos a utilizacão da miniesternotomia inferior como abordagem para o tratamento de pacientes com lesão única de ADA, com anastomose do enxerto de artéria torácica interna esquerda (ATIE), sem uso de circulacão extracorpórea (CEC). MÉTODO: Foram estudados 14 pacientes operados consecutivamente utilizando esta técnica, na qual o enxerto de ATIE foi anastomosado à ADA. A idade média dos pacientes foi 56,7n10,1 anos. A incisão cutânea tinha entre 7 e 9 cm e a porcão inferior do esterno foi aberta longitudinalmente. A anastomose foi facilitada com o uso de estabilizadores Octopus-3® (Medtronic). RESULTADOS: Todos os pacientes tiveram boa evolucão pós-operatória, com alta hospitalar entre 2 e 6 dias de PO (mediana 3 dias). Não houve alteracão de ECG ou elevacão enzimática neste grupo. Um paciente foi reinternado por infeccão de ferida operatória. CONCLUSAO: A miniesternotomia permite a realizacão segura do procedimento cirúrgico de revascularizacão miocárdica da ADA, sem CEC, com benefício em longo-termo do uso da ATIE.


Subject(s)
Adult , Aged , Male , Female , Humans , Sternum/surgery , Myocardial Revascularization/methods , Cardiac Surgical Procedures/instrumentation , Retrospective Studies
11.
Rev. SOCERJ ; 18(6): 516-526, nov.-dez. 2005. tab
Article in Portuguese | LILACS | ID: lil-434756

ABSTRACT

Objetivo: Criar um escore preditivo de mortalidade hospitalar em pacientes submetidos à cirurgia carddíaca e admitidos em duas Unidades de Terapia Intensiva Cirúrgica, analisando variáveis pré, per e de primeiro dia de pós-operatório.Métodos: Coorte clássica de 1458 pacientes internados consecutivamente no período de junho 2000 até março de 2003, com 46 variáveis previamente definidas. a análise estatística consistiu em análise univariada, seguida de regressão logística (RL), com teste de tendência linear e curva ROC.Resultados:Após, as variáveis selecionadas com os respectivos OR foram: idade entre 65 e 75 anos (2,05);idade maior ou igual 75 anos (4,79); diâmetro do átrio esquerdo maior 45mm (2,58)...


Subject(s)
Humans , Aged , Thoracic Surgery/instrumentation , Thoracic Surgery/methods , Thoracic Surgery/trends , Postoperative Care/rehabilitation , Postoperative Care/trends , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/methods , Cardiac Surgical Procedures/mortality , APACHE , Logistic Models , ROC Curve , Myocardial Revascularization/methods , Myocardial Revascularization/mortality , Myocardial Revascularization/trends
12.
Rev. SOCERJ ; 18(5): 477-479, set.-out. 2005. ilus
Article in Portuguese | LILACS | ID: lil-428682

ABSTRACT

Paciente do sexo feminino, sem patologias prévias, após episódio de aborto espontâneo foi submetida à curetagem uterina.Em seguida, desenvolveu quadro de endocardite aguda com vegetação volumosa, friável, aderida à valva tricúspide e hemocultura positiva para Streptococcus agalactiae.Apesar de terapia clínica e cirúrgica não houve melhora do quadro, evoluindo para óbito.


Subject(s)
Female , Adult , Humans , Endocarditis/complications , Endocarditis/diagnosis , Endocarditis/mortality , Streptococcus agalactiae , Streptococcus agalactiae/physiology , Streptococcus agalactiae/metabolism , Tricuspid Valve/surgery , Tricuspid Valve/physiopathology , Abortion, Spontaneous , Cardiac Surgical Procedures/instrumentation , Cardiac Surgical Procedures/mortality
13.
Arch. cardiol. Méx ; 75(supl.3): 10-20, jul.-sep. 2005. ilus
Article in Spanish | LILACS | ID: lil-631936

ABSTRACT

Diversas enfermedades congénitas o adquiridas incrementan la presión sistólica del ventrículo derecho. Este incremento se ha realizado con el bandaje del tronco arterial pulmonar con cintas de lino o dispositivos hidráulicos. Presentamos un nuevo dispositivo hidráulico para ser usado en sujetos experimentales menores a 15 kilogramos. Material y métodos: Se realizó una fase experimental de laboratorio donde los dispositivos hidráulicos fueron probados contra presiones hasta de 80 mm Hg; posteriormente se colocaron en el tronco de la arteria pulmonar de perros donde se les determinó la presión sistólica del ventrículo derecho, la de la arteria pulmonar y el gradiente de ambos. Los valores se expresaron en medias ± desviación estándar. Resultados: El peso de los perros fue 12.6 ± 2.2 kilogramos. El diámetro del tronco de la arteria pulmonar encontrado en los perros fue de 12.4 ± 1.4 mm y 27.5 ± 1.6 mm de largo. Las presiones sistólicas ventriculares derechas en condición basal y de máxima elevación fueron: 25.5 ± 1.9 mm Hg vs 50.3 ± 6.9 mm Hg, p < 0.0001; las presiones sistólicas de la arteria pulmonar para estas mismas condiciones fueron: 24.7 ± 2 mm Hg vs 21.5 ± 6.9 mm Hg, p < 0.043; y el respectivo gradiente de ambas para estas presiones fueron: 0.8 ± 1.4 mm Hg vs 28.8 ± 4.2 mm Hg, p < 0.0001. Conclusiones: El DH permite el incremento agudo controlado de la presión sistólica del ventrículo derecho.


Different congenital or acquired diseases increase the right ventricular systolic pressure. The elevation is achieved by pulmonary artery banding with linen tape or hydraulic devices. We introduce a new hydraulic device to be used in experimental subjects of less than 15 kilograms. Methods: An experimental laboratory phase was conducted. In this phase, the hydraulic devices were tested against pressures as high as 80 mm Hg; later on the hydraulic devices were placed on the dogs' main pulmonary artery; the right ventricular systolic pressure, pulmonary artery pressure, and their differences were obtained. The values are expressed in average ± standard deviation. Results: The average weight of the dogs was 12.6 ± 2.2 kg. The average diameter found in the main pulmonary artery was 12.4 ± 1.4 mm and 27.5 ± 1.6 mm length. Right ventricular systolic pressure of basal condition to maximum pressure obtained was 25.5 ± 1.9 mm Hg vs 50.3 ± 6.9 mm Hg, p < 0.0001; pulmonary artery pressures under the same conditions were 24.7 ± 2 mm Hg vs 21.5 ± 6.9 mm Hg, p < 0.043; and the differences between them were 0.8 ± 1.4 mm Hg vs 28.8 ± 4.2 mm Hg, p < 0.0001, developed by the hydraulic device respectively. Conclusions: The hydraulic device allows attaining a controlled acute increase in right ventricular systolic pressure.


Subject(s)
Animals , Dogs , Pulmonary Artery/surgery , Cardiac Surgical Procedures/instrumentation , Equipment Design , Cardiac Surgical Procedures/methods , Ligation/instrumentation , Ligation/methods
14.
Arq. ciênc. saúde ; 12(2): 116-119, abr.-jun. 2005. ilus
Article in Portuguese | LILACS | ID: lil-431145

ABSTRACT

O objetivo da drenagem torácica é remover uma coleção de líquido ou ar alojado na cavidade pleural, para recuperar a expansão pulmonar, e evitar conseqüências secundárias. A inserção de um dreno torácico durante a cirurgia cardíaca permite a drenagem de ar ou líquido da cavidade pleural. A retirada do dreno de tórax dos pacientes submetidos à cirurgia cardíaca, geralmente ocorre no segundo pós-operatório, sendo um procedimento realizado por médicos e enfermeiros e que requer conhecimentos e habilidades técnicas, devido à sua complexidade. Pelo fato de ser uma técnica também realizada por enfermeiros diariamente nas unidades coronarianas e de cirurgia cardíaca, este estudo foi realizado com o objetivo de esclarecer e elaborar um roteiro para o procedimento.


Subject(s)
Humans , Postoperative Care/instrumentation , Drainage , Nursing, Team , Cardiac Surgical Procedures/instrumentation , Thoracostomy , Thorax
15.
Rev. bras. cir. cardiovasc ; 20(1): 85-87, Jan.-Mar. 2005. ilus
Article in Portuguese | LILACS | ID: lil-413213

ABSTRACT

Paciente de 61 anos procurou atendimento médico com quadro clínico de infecção pulmonar. O estudo radiológico de tóraz revelou aneurisma de aorta descendente com comprometimento do arco aórtico. Ressalta-se a correção cirúrgica em uma única etapa, por meio de abordagem operatória não convencional, que possibilitou a correção total do aneurisma


Subject(s)
Humans , Male , Aged , Aortic Aneurysm, Thoracic/surgery , Aorta/abnormalities , Aorta/surgery , Extracorporeal Circulation , Voice Disorders/diagnosis , Cardiac Surgical Procedures/instrumentation
16.
Rev. bras. cir. cardiovasc ; 19(2): 171-178, abr.-jun. 2004. ilus, tab
Article in Portuguese | LILACS | ID: lil-383654

ABSTRACT

O desenvolvimento de sistemas robóticos para cirurgia teve início na década de 80, por solicitação do exército norte-americano, que antevia a possibilidade de realizar operações em teatros de guerra, distantes do local onde estava o cirurgião. Entretanto, o primeiro uso em humanos só ocorreu anos mais tarde, numa ressecção transuretral de hiperplasia benigna de próstata. Cirurgiões cardíacos foram logo atraídos pela técnica robótica devido a possível aplicação com reduzido caráter invasivo; esperava-se menor trauma cirúrgico e redução da dor, morbidade, tempo de internação e custo do procedimento. Atualmente, de forma restrita e em casos selecionados, robôs são usados para revascularização do miocárdio e implante de marcapasso em cirurgias cardíacas totalmente endoscópicas; podendo também constituir apoio visual na retirada de artéria torácica interna, reconstrução valvar mitral e correção de defeitos congênitos. Utilizando o robô auxiliar AESOP® para controle do videotoracoscópio, com controle vocal por meio do sistema HERMES®, temos realizado dissecção da artéria torácica interna, implante de eletrodo ventricular esquerdo e abordagem de defeitos congênitos na cirurgia de correção. Apesar do entusiasmo científico inicial com a cirurgia robótica, ainda não existe evidência clara de superioridade desta técnica em relação à operação convencional, em termos de resultado. Isto se aplica também ao custo, pois o investimento inicial na aquisição de sistema cirúrgico completo (console, controle de vídeo, instrumental) provavelmente é compensado após muitos procedimentos e longo intervalo. Mas é certo que a cirurgia robótica terá um lugar no futuro, possibilitando aprendizagem, telepresença e realização de procedimentos pouco invasivos, embora complexos.


Subject(s)
Cardiovascular Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Cardiac Surgical Procedures/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL